Fujitsu BX600 S2 Server User Manual


 
62 PRIMERGY BX600 S2 Basic Unit
Updating BX600 System Components Preparation for Use and Operation
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: H:\windows\_projekte\Bxz\Betriebsanleitung\Version_Maerz-2007\Archiv\BX600S2_en\blade-us.k05
Figure 23: Updating the server blade BMC via the web interface
5.4.2 Updating the Management Blade Firmware
V CAUTION!
The procedure described below must be performed for each of the two
management blades.
Proceed as follows:
Ê Install your TFTP server software and start it. Copy the relevant firmware file
(*.bin) to the root directory of the TFTP file system.
Ê Check the LAN connection by pinging the relevant management blade.
Ê Enter the IP address of the TFTP server which provides the BMC image file
for the management blade firmware. Enter the path and the file name of the
image file for the management blade.
You have two options for doing this:
1. In the management console (Telnet) select the TFTP Upgrade submenu.
Activate the option Management Blade/TFTP Update.
2. In the web interface of the management blade, select the entry System
Property - Environment Maintenance - Firmware Update - Management Blade
BMC Update.