Figure 24: Updating the management blade firmware via the web interface
Ê Make sure that both management blades are connected to the LAN.
Ê Enter the IP address of the TFTP server on which the image file for the
management blade firmware is provided.
Ê Enter an IP address in the Agent Update IP Address field.
I The IP address in the Agent Update IP Address field is only used tempo-
rarily, so you can enter any IP address that is not used in the LAN
segment of the server.
Ê In the Boot Image File Name field, enter the name of the image file of the
management blade.
Ê Set the value of the TFTP Update Enable field to enable.
Ê Click Apply.
The firmware of the first management blade (Master) will now be updated
(the green LED lights up). When the update process is complete, this
management blade is defined as the Slave, and the second management
blade, which used to be the Slave, is now defined as the Master.
Ê Repeat the update process for the second management blade.
After the update process for the second management blade, the original