184
Chapter 9: Event Logs
www.gateway.com
Drive events
These events are related to the drive bus and arrays.
Drive Event Messages Description Cause Action
Array xx Critical This indicates the specified
array is critical.
Drive removal or
failure.
Replace the hard
drive and rebuild
the array.
Array
xx
Expansion Started Expansion of the indicated
array has started.
Expansion has
started.
No action
necessary.
Array
xx
Expansion
Restarted
Expansion of the indicated
array has restarted, after a
power cycle or
failover/failback.
Expansion has
restarted.
No action
necessary.
Array
xx
Expansion
Complete
Expansion of the indicated
array has completed.
Expansion has
completed.
No action
necessary.
Array
xx
Initialization
Started
Initialization of the indicated
array has started.
Initialization has
started.
No action
necessary.
Array
xx
Initialization
Complete
Initialization of the indicated
array has completed.
Initialization has
completed.
No action
necessary.
Array
xx
Parity
Check/Rewrite/Check and
Rewrite Started
These events indicate that a
RAID 5/50 Parity Check,
Rewrite or Check and
Rewrite has started.
Parity check
started.
No action
necessary.
Array
xx
Parity
Check/Rewrite/Check and
Rewrite Completed, yy
Errors
These events indicate that a
RAID 5/50 Parity Check,
Rewrite, or Check and
Rewrite has completed. Any
errors are indicated.
Parity check
completed.
No action
necessary.
Array
xx
Parity
Check/Rewrite/Check and
Rewrite Aborted,
yy
Errors
These events indicate that a
RAID 5/50 Parity Check,
Rewrite, or Check and
Rewrite has been stopped.
Any errors up to this point
are indicated.
Parity check
canceled by the
user.
No action
necessary.