Gateway E-842R Server User Manual


 
www.gateway.com
31
Power consumption
Power consumption of enclosure with 12x SAS drives running I/O, powered by a single power
supply module (Power One power supply module) with extended power lead between the power
supply module and the I/O backplane and with two controllers installed at IDLE and ACTIVE
operation.
Power supply module safety and EMC compliance
Environment
Caution
The enclosure must be operated with two power supplies in place.
Voltage Rail IDLE ACTIVE
Average Peak Average Peak
5V 11.51 A 13.2A 13.53A 15.7A
12V 12.29A 15.1A 13.17A 20.1A
Safety compliance UL 60950-1
IEC 60950-1
EN 60950-1
EMC compliance CFR47 Part 15B Class A
EN55022
EN55024
Temperature Range Relative Humidity Max. Wet Bulb
Operational
41°F to 104°F (5°C to
40°C)
8% to 80%
non-condensing
73.4°F (23°C)
Non-Operational
33.8°F to 122°F (1°C to
50°C)
8% to 80%
non-condensing
80.6°F (27°C)
Storage
33.8°F to 140°F (1°C to
60°C)
8% to 80%
non-condensing
84.2°F (29°C)
Shipping
-40°F to 140°F (-40°C to
60°C)
5% to 100%
non-precipitating
84.2°F (29°C)
Airflow
The system must be operated with a low pressure rear exhaust
installation (the back pressure created by the rack doors and obstacles
not to exceed 5 pascals [0.5mm Water gauge])
Altitude, Operational
0 to 10,000 ft. (0 to 3045 m)
Altitude, Non-Operational
-1000 to 40,000 ft. (-305 to 12,192 m)