15
System Overview
System Unit Rear Panel Connectors
Security Loop
The security loop provides a means of locking the storage tray, with a pad-
lock or other locking device, to prevent unauthorized removal from the sys-
tem.
Audio Connectors
Your workstation has audio input and output capability through external
input and output connectors on the rear panel and through an internal
speaker. The rear panel contains the Audio IN (stereo line-in) and Audio
OUT (stereo line-out) connectors.
NOTICE: To maintain compliance with FCC/CISPR B you must use fully shielded,
unbalanced audio cables and plugs.
The audio connectors are standard stereo audio mini-jacks. Hewlett-Packard
recommends using gold-plated plugs available through audio retailers for
best quality recording and playback through the external connectors. The
following is a summary of the workstation audio features:
Audio Features
Programmable sample rates:
8kHz, 16kHz, 32kHz, 48kHz, 11.025kHz,
22.05kHz, and 44.1kHz.
Programmable output attenuation:
0 to -96dB in -1.5dB steps
Programmable input gain:
0 to 22.5dB in 1.5dB steps
Input monitoring:
16-bit linear, 8-bit u-law, or A-law coding
Audio Input
Line In
Mono microphone (on the front panel) compatible with
1.5V phantom supply (bias voltage supplied by the