4 - 55
Disconnect UPS Battery
Equipment Required
The following equipment is user-supplied:
• Torquing tool capable of measuring inch pounds
• #2 Phillips screwdriver bit
Disconnect Procedure
CAUTION - The UPS battery must be disconnected before you ship the Thor VM1, Replace UPS Battery (page 4-60) or
Replace Front Panel (page 4-58).
1. For convenience, the Thor VM1 can be removed
from the Quick Mount Smart Dock, though it is not
necessary.
2. If the Thor VM1 remains in the dock, disconnect
the power cable from the dock.
3. Shutdown the Thor VM1.
4. Place the Thor VM1 face down on a stable
surface.
5. Using a #2 Phillips bit loosen the M3 screws and
then remove the tethered access panel with the
SIM label. This panel is on the right hand side
when the Thor VM1 is face down with the top
away from the user.
6. Locate the small push button located just below the SIM card installation slot..
7. Press the push button to disconnect the UPS. The UPS battery maintains its charge but is
disconnected from the power circuitry of the Thor VM1.
8. Reattach the access panel, torquing the M3 screws to 4-5 inch pounds using a #2 Phillips bit.
9. When the Thor VM1 is attached to external power, the UPS battery is automatically
reconnected.
10. Restart the Thor VM1.
!