IBM 360X (2620) Laptop User Manual


 
Numeric Error Codes
Symptom/Error FRU/Action
10X 1. System Board
110 1. Go to “Memory
Checkout” on
page 201.
2. IC DRAM Card or
DIMM Card
3. System Board
111 1. Go to “Memory
Checkout” on
page 201.
2. Expansion Unit/Port
Replicator
3. System Board
118
(Memory parity error was
logged in CMOS.)
(Go to “Memory Checkout”
on page 201.)
1. Run memory
diagnostics to clear
the error log.
158
(HDP was not set even
though the supervisor
password is set.)
1. Set a HDP.
159
(HDP is not set the same as
the supervisor password.)
1. Set a correct HDP.
161 1. Go to “Checking the
Backup Battery” on
page 211.
2. Backup Battery
3. System Board
163
(Time and Date was not
set.)
1. Set Time and Date.
2. System Board
173
(Configuration data were
lost.)
1. Select OK in the error
screen; then set time
and date
2. Backup Battery
3. System Board
174
(Perform “Checking the
Installed Devices List” on
page 230 before changing
any FRUs.)
1. Check Device
Configuration.
2. System Board
3. Diskette Drive
Assembly
4. Hard Disk Drive
Assembly
175, 177, 178 1. System Board
183
(Incorrect password entered
at the supervisor password
prompt.)
1. Have the user
examine the
password.
184
(POP check sum error.)
1. Reset the POP in
Easy-Setup.
ThinkPad 355x, 360x, 370C, 750x, 755C, 755Cs 217