IBM 360X (2620) Laptop User Manual


 
Symptom/Error FRU/Action
163
(Time and Date was not
set.)
1. Set Time and Date.
2. System Board
173
(Configuration data were
lost.)
1. Select OK in the error
screen; then set time
and date.
2. Backup Battery
3. System Board
174
(Perform “Checking the
Installed Devices List” on
page 346 before changing
any FRUs.)
1. Check Device
Configuration.
2. System Board
3. Diskette Drive
Assembly
4. Hard Disk Drive
Assembly
175, 177, 178 1. System Board
183
(Incorrect password entered
at the supervisor password
prompt.)
1. Have the user
examine the
password.
184
(POP check sum error.)
1. Reset the POP in
Easy-Setup.
185
(The startup sequence is
not valid. Suspect that
power was off when the
startup sequence was being
updated.)
1. Reset the startup
sequence in
Easy-Setup.
186 1. System Board
188 1. Set the system
identification using
the ThinkPad 750Ce
hardware
maintenance diskette.
190
(Depleted battery pack was
installed when the power
was on.)
1. Go to “Checking the
Battery Pack” on
page 324.
191XX 1. System Board
2. Processor card
195
(The configuration read from
the hibernation area does
not match the actual
configuration.)
1. Check if the
configuration was
changed.
For example, check if
the disk drive is from
another computer.
196
(Read error occurred in the
hibernation area of the
HDD.)
1. Run the hard disk
drive test.
2. Hard Disk Drive
199XX 1. System Board
1XX 1. System Board
332 IBM Mobile Systems HMM