IBM 9306 Personal Computer User Manual


 
Installing the Flat Panel Monitor Console Kit
The Flat Panel Monitor Console Kit occupies 1U of rack mounting space in a rack
cabinet. You can install an optional console switch, using the brackets that come
with this kit, in the same 1U of rack mounting space.
Attention: The Flat Panel Monitor Console Kit comes already assembled. You
must have at least 3U of rack mounting space available in your rack cabinet to
install the kit. After you install the Flat Panel Monitor Console kit, you can install
other devices in your rack cabinet above or below the kit.
Installing the flat panel monitor and keyboard tray
Two people are required to install the flat panel monitor and keyboard tray. Use the
following procedure to install the kit in a rack cabinet:
Statement 4:
DANGER
Electrical current from power, telephone, and communication cables is
hazardous.
To avoid a shock hazard:
v Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
v Connect all power cords to a properly wired and grounded electrical
outlet.
v Connect to properly wired outlets any equipment that will be attached to
this product.
v When possible, use one hand only to connect or disconnect signal
cables.
v Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
v Connect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached
devices.
To Connect: To Disconnect:
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
5. Turn device ON.
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
1U Flat Panel Monitor Console Kit 87