TCT review the entire table, particularly for BTAM changes. Add
CONSLID=console designation for MVS Multiple Console Support
(MCS). You must remove any spool parameter associated with
CICS/VSE Report Controller Feature (RCF).
SIT review all the entries since there are VSE and MVS only parameters.
Plus, there are new and different suffixes for the pregenerated
CICS/MVS management modules. For example:
ABDUMP is removed because of CICS reconstructed dump facilities.
AIEXIT provides the user-replaceable autoinstall program name
(was the second value for CICS/VSE autoinstall SIT
parameter).
AILDELAY is the delete delay period for autoinst (was the fourth value
for CICS/VSE autoinstall SIT parameter).
AIQMAX maximum number of term queued for autoinst (was the
first value for CICS/VSE autoinstall SIT parameter).
AKPFREQ this parameter now represents the number of write
operations to the log stream buffer before an activity
keypoint is taken. The default value is now 4000 instead of
200.
AMXT is obsolete, with the new CICS dispatcher algorithms which
removed the need to limit the number of active tasks.
AUTINST is replaced by the AIEXIT parameter.
COBOL2 is obsolete, CICS will initialize it immediately if the
COBOL2 library is available.
CMXT is replaced by the MAXACTIVE parameter that is provided
on the new TRANCLASS resource definition.
DBP is obsolete, and all backout is now coordinated by the
recovery manager.
DBUFSZ is obsolete--all CICS system log output is written directly to
the system log stream.
DCT the COLD option is removed, and the default is changed
from YES to NO.
DLI is obsolete for both local and remote DL/I support.
FERS is obsolete.
ICVR 0 is the default if RUNAWAY(SYSTEM). You may have
found it necessary to specify an artificially high ICVR value,
to allow processor intensive transactions to run without
being abended as runaway tasks. In CICS/ESA you can
specify individual runaway timeout values on the
transaction resource definition. This means that you can
lower your ICVR value to a realistic limit for the average
transactions, and have the definition for these reference
the global ICVR limit by means of the RUNAWAY(SYSTEM)
attribute.
ICVS is obsolete.
142 VSE to OS/390 Migration Workbook