IBM RS/6000 Server User Manual


 
Sample File modem_f1.cfg
#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP F1
#
# FUNCTIONS: Modem configuration file for many recent Hayesᑍ compatible modems.
# This example uses the AT&F1 reset command to choose the factory defaults.
# This set up is for modems with extended (&) commands and which do not work
# properly with setup F. For early vintage modems, setup Z or Z is
# recommended.
#
# ᑍ Trademark of Hayes Microcomputer Products, Inc.
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials - Property of IBM
#
# US Government Users Restricted Rights - Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
#
# If the modem has configuration switches, they should be set to the
# factory default settings.
ICDelay 1
DefaultTO 1
CallDelay 12
# AT Attention Code , Inserts delay in dialing commands
# &F1 Reset. Restore profile 1 Q Turn on responses
# E Turn echo off Q1 Turn off responses
# V Use numeric responses S= Automatic answer inhibit
# +++ Escape to command mode S=2 Answer on second ring
# H Hang-up X= Limit modem response codes
# T = Tone mode. When used as T\r, it is a
# no op to maintain program synchronization
# when modem may/will echo the commands.
#
# &C1 Detect CD &D2 Respond to DTR (often the default)
# &R1 Ignore RTS (CTS)
#
# %N Call-Out phone number %P Paging phone number
# %S Modem speed (available to users)
#
# Following are common responses from a wide range of modems:
# 16, 15, 12, 1, 5 and 1 are connection responses. Add others as required.
# 7=busy; 6=no dial tone; 4=error; 3=no carrier; 2=ring; =OK
#
# PROGRAMMING NOTE: No blanks between double quote marks (").
condout: send "AT&F1QT\r" # Reset modem. Select profile 1
ignore "\r" or "OK\r\n" timeout 2 # Ignore modem response.
send "ATET\r" # Initialize modem: Echo OFF,
expect "\r" or "OK\r\n" timeout 2 # Enable responses (Numeric),
send "ATQVXT\r" # Limit response codes.
expect "\r" timeout 2 # Confirm commands successful.
send "ATS=\r" # Set AutoAnswer OFF
expect "\r" timeout 2 # Confirm command successful.
send "AT&C1&D2&R1\r" # Detect carrier and DTR,
# Ignore RTS.
expect "\r" timeout 2 # Confirm command successful.
done
connect: send "ATDT%N\r" # Tone dialing command.
# %N from Call Home setup.
# Expect a connection response.
expect "16\r" or "15\r" or "14\r" or "12\r" or "1\r" or "5\r" or "1\r" busy "7\r"
Appendix C. Modem Configurations C-25