IBM RS/6000 7025 Personal Computer User Manual


 
Step 14
The diagnostics produced an SRN for this problem.
1. Record the SRN and other numbers read out.
2. Report the SRN to the service organization.
3. STOP. You have completed these procedures.
Step 15
When you are loading the Standalone Diagnostics, the attributes for the terminal
must be set to match the defaults of the diagnostic programs. The ASCII terminal
must be attached to serial port 1 on the system unit.
Are you going to load Standalone Diagnostics and run them from a ASCII
terminal?
NO Go to “Step 16.”
YES Go to “Running the Diagnostics from a TTY Terminal” on page 6-3 and
be sure your terminal attributes are set to work with the diagnostic
programs.
Return to “Step 16” when you finish checking the attributes. Record any
settings that are changed.
9-8
IBM RS/6000 7025 F50 Series User's Guide