Intel 80200 Computer Hardware User Manual


 
Developers Manual March, 2003 C-7
Intel
®
80200 Processor based on Intel
®
XScale
Microarchitecture
Test Features
C.2.5 TAP Controller
The TAP controller is a 16-state synchronous finite state machine that controls the sequence of test
logic operations. The TAP can be controlled via a bus master. The bus master can be either
automatic test equipment or a component (i.e. PLD) that interfaces to the Test Access Port (TAP).
The TAP controller changes state only in response to a rising edge of TCK or power-up. The value
of the test mode state (TMS) input signal at a rising edge of TCK controls the sequence of state
changes. The TAP controller is automatically initialized on powerup. In addition, the TAP
controller can be initialized by applying a high signal level on the TMS input for five TCK periods.
Behavior of the TAP controller and other test logic in each controller state is described in the
following subsections. For greater detail on the state machine and the public instructions, refer to
IEEE 1149.1 Standard Test Access Port and Boundary-Scan Architecture Document.
Figure C-2. TAP Controller State Diagram
B1309-01
1
TEST-LOGIC-
RESET
0
1
1
1
11
0
1
1
SELECT -
DR - SCAN
0
SELECT -
IR - SCAN
0
CAPTURE - DR
0
0
0
0
RUN-TEST /
IDLE
0
CAPTURE - IR
SHIFT - DR
1
1
SHIFT - IR
EXIT1 - DR
0
0
EXIT1 - IR
PAUSE - DR
1
1
PAUSE - IR
EXIT2 - DR
1
1
EXIT2 - IR
UPDATE - DR
1
100
UPDATE - IR
NOTE: All state transitions are based on the value of TMS.
0
0
0
TRST#=0