Intel ISP1100 Server User Manual


 
48 Intel ISP1100 Internet Server Product Guide
Installing the Riser and Add-in Card(s)
Perform this procedure to install the riser and add-in card(s) in the server PCI expansion slots.
Refer to Figure 27 while performing this procedure.
1. Align the riser card edge connector (A) with the mating riser connector on the server board.
(The connectors are keyed to mate in only one direction.)
NOTE
If you installed a low-profile card on the riser, make sure the right side of the low-
profile card bracket (B) fits into the narrow slot (C) on the right side of the add-in
card expansion slot.
2. Firmly press the riser/add-in card(s) straight down and all the way into the mating connector on
the server board.
CAUTION
If you installed only one add-in card, make sure the empty expansion slot has a filler
panel installed before you attach the filler panel retention bracket as described in the
following step. An open expansion slot will reduce the cooling and EMI integrity of
the server.
3. Use the Phillips screwdriver and the two screws (D) removed in the “Removing the Rear I/O
Filler Panel(s)” procedure to securely attach the filler panel retention bracket (E) to the top of
the server back panel.
CAUTION
If you installed only one add-in card, make sure the empty expansion slot has a filler
panel installed. An open expansion slot will reduce the cooling and EMI integrity of
the server. Refer to the preceding “Installing the Rear I/O Filler Panel(s)” procedure.
D
E
B
C
A
OMO9440
Figure 27. Installing the Riser and Add-in Card(s)