KZPCM PCI–to–Dual Channel Ultra SCSI and 10/100MB Ethernet Host Adapter
5–8 EK–KZPCM–UG. B01
4. Execute the installation DCL command procedure:
$
@ITI_INSTALL
5. The
iti_install
procedure will automatically:
•
Move the correct version of the driver to your
SYS$LOADABLE_IMAGES
directory;
•
Move the automatic configuraton (
ICBM
) program to your
SYS$SYSTEM
directory;
•
Modify your
SYS$USER_CONFIG.DAT
file for VMS V7.1-1H2.
When
iti_install
exits, your adapter(s) are configured, and disks on the adapters
are available for use.
5.3 Changing the SCSI ID of the Host Adapter (VMS)
At the SRM console (indicated by a >>> or P0> prompt at the system console)
storage controllers are identified by the port class prefix PK.
The command
>>>
show dev pk
displays all known disk adapters. When you
have identified the location of the adapter you wish to change the ID of, issue the
following command:
>>>
set pkb0_host_id 6
(this example changes the PKB host
adapter ID to 6 from the default of 7)
Verify the change with:
>>>
show pkb0_host_id
Be sure you do not pick an ID that conflicts with other devices on the bus.