Section 8: Barcodes
Invalid Interleaved 2of5 command:
Four characters are specified in the Data Transfer Command. The first three
characters, "058", are in the character set for Interleaved 2of5. The fourth
character,’ $’, is not valid for Interleaved 2of5.
UPC-A
UPC-A is an all-numeric, fixed-length symbology.
k value: 183, xB7
m value: 0 to 4, x00 to x04
s value: -3 to 3, xFD to x03
minimum v1, v2 values: x0E, x01 (248x)
x20, x01 (249x)
c parameter: available functions:
b0, check digit
b1, human readable
b2, flag character position
n1 value (b0 = 0): 12, x0C
n1 value (b0 = 1): 11, x0B
n2 value: 0, x00
<x
1B5B66 - barcode setup command prefix
0600 - setup data length (low byte first) - x0006, 6
B6 - barcode type = Interleaved 2of5
00 - module width = default
00 - space width adjustment = default
4003 - height (low byte first) - x0340 = 832 = 0.385
inches
00 - control byte: check digit from host, print
human readable character
1B5B70 - barcode data transfer command prefix
0400 - data transfer length (low byte first) -
x0004, 4
>058$ ...