Lexmark 4059-XXX Printer User Manual


 
Diagnostic Aids 3-16
4059-XXX
Output Bin Sensor Test
This test is used to verify if the output bin sensors are working
correctly.
To run the Output Bin Sensor Test:
1. Select Sensor Test from the Output Bin Test menu.
"Output Bin/Full=OP/Input=OP" message displays.
Full = Output Bins Full Sensor
Pass = Output Bins Pass Thru Sensor
2. Once the message displays, the servicer can manually actuate
each of the output bin sensors. The bin full sensor can be
actuated by hand, however a sheet of paper can be used to
cover the bin's pass thru sensor. When the sensor is closed CL
displays, and when the sensor is open OP displays.
3. Press Return/Stop to exit the test.
Output Bin X Sensor Test
Note: Some output expanders have a single output bin sensor
installed while others have a dual sensor assembly. Both versions
have a single pass thru sensor. This test is used to verify if the
Output Bin X sensors are working correctly.
To run the Output Bin X Sensor tests:
1. Select Output Bin tests from the menu.
2. Select Output Bin tests - Sensor Tests.
3. Select Sensor Tests - Output Bin X.
Output Expander with Single Sensor
The following is displayed:
Output Bin X
Full=OP P=OP
Full=Bin Full Sensor
P=Pass Thru Sensor