Nortel Networks 425 series Switch User Manual


 
124 Configuring the domain
/cfg/domain/location/locations
followed by:
del <index number> Removes the locations from the
configuration.
index number—specify the index
number.
unit/port—specify the
Unit/Port.
list lists all the configured locations.
Configuring Lumension PatchLink integration
Nortel SNAS is integrated with the Lumension PatchLink security patch
management system, which allows to proactively enforce user and device
compliance by ensuring that devices are properly patched and up-to-date.
PatchLink server is a patch and vulnerability management solution. It
works in an Agent mode, where an installed agent (system service)
communicates to a central PatchLink server and updates the system as
and when patches are available. Patchlink solution is integrated to verify
the compliance status of the client with Nortel SNAS.
To create the patchlink server, use the following command:
/cfg/domain/patchlink
The PatchLink Servers menu appears.
The PatchLink Servers menu includes the following options:
/cfg/domain/patchlink
followed by:
add <IP address> <username>
<password>
Adds a patch link server.
IP address—specify the IP
address.
username—string that specifies a
unique user login name.
password—the password that
applies to the user you specified.
Nortel Secure Network Access Switch
Using the Command Line Interface
NN47230-100 03.01 Standard
28 July 2008