Nortel Networks 555-4001-135 Server User Manual


 
Browser user interface 109
Nortel Integrated Conference Bridge Service Implementation Guide
Table 23
General Settings window fields
Field Description
Administration
E-mail
Enter the E-mail address to which the ICB sends administration material,
including backup files.
Billing option Select a billing option for this card from the pull-down menu. The options are as
follows:
No billing – The ICB does not issue a billing report.
Billing reports – The ICB issues a billing report (see “Billing Report” on
page 202).
Billing reports & CDR – The ICB issues a billing report and a CDR record
(see
“CS 1000 Call Detail Recording” on page 207).
Note: The Billing reports & CDR record option is not available on the Meridian SL-100.
Card ID (4 digits) Enter the card ID that the system uses for billing purposes.
Range: A four-digit decimal.
Ports overbooking Enter the number of ports the Overbooking feature adds. The available values
are shown in the form of 32 + N, where 32 is the physical capacity and N is the
addition for overbooking.
Range: From 32 + 0 (no overbooking) to 32 + 8 for cards with 32 ports. In cards
with less than 32 ports, the maximum N is the proportional fraction of 8 (for
example, 16 + 4 for a card with 16 ports).
Default: N = 0 (no overbooking).
Reserve port for
TUI
Click in the box to dedicate one of the card’s ports for TUI access, which is not
available for meetings. When this box is not checked, the system does not
reserve a port for the TUI; when all ports on the ICB are busy the TUI is
inaccessible.
Name recording
length
Enter the duration, in seconds, of the spoken name in the name-entry option.
When the system prompts the callers for their name, recording after the beep
takes place for the specified duration.
Range: 2-10 seconds.
Default: 2 seconds.
Conference
auto-generated
password length
Enter the number of digits for the conference or chairperson password, when a
user selects the password to be automatically generated by the ICB.
Meeting closed
second warning
message
Click the box to have hear the second warning message 2 minutes before ending
the meeting.