Nortel Networks 555-4001-135 Server User Manual


 
184 Maintenance
553-3001-358/555-4001-135 Standard 02.00 July 2006
Error message procedures
Follow the steps in Procedure 37 to view the on-line error message
documentation.
Procedure 37
Access the on-line error message analysis tool
1 Access the CLI SM directory and enter the following:
SHO
The CLI prompts you for to enter the error code.
2 Enter the error code for which you want information:
For example, enter:
MNGMMI109
Note: The letters are case sensitive and must be entered exactly as they
appear in the error message.
The CLI prints the following related information about the message:
<Syntax> – definition of the message syntax.
Meaning – shows what the message indicates.
Parameters – description of the message parameters (fields).
<error code> Unique identifier of the event being reported. It is made up of the following two
parts:
a string of up to six letters indicating the firmware component that originates
the message
three decimal digits comprising the error number within this component
<timestamp> Date and time of the message in the format MM-DD hh:mm:ss:ff, where:
MM = month number.
DD = day of the month.
hh = hour (in 24-hour format).
mm = minutes.
ss = seconds.
fff = fraction of second, in milliseconds.
<error text> Short description of the problem or event, and related parameters (for example,
port number).
Table 48
Error message field formats (Continued)
Field Description