Nortel Networks 555-4001-135 Server User Manual


 
Installation and configuration 49
Nortel Integrated Conference Bridge Service Implementation Guide
Enter the CS 1000 definitions for the Phantom TN in LD 10 as follows:
1 The specific TN and DN vary by site.
Those variables are represented by “x” in Figure 9 on page 49.
2 CFXA is the Class of Service (CLS) that enables Call Forwarding.
3 The last four variables in the screen (under FTR) are the main ACD
DNs in LD 23.
Figure 9
Phantom TN definitions (LD 10)
The next step is to configure ICB ports as digital sets.
DES MICB
TN xxx x xx xx PHANTOM
TYPE 500
CDEN 4D
CUST 0
WRLS NO
DN xxxx x MARP
AST NO
IAPG 0
HUNT
TGAR 1
LDN NO
NCOS 0
SGRP 0
RNPG 0
XLST
SCI 0
SCPW
SFLT NO
CAC 3
CLS CTD DTN FBD XFD WTA THFD FND HTD ONS
LPR XRD CWD SWD MWD LPD XHD CCSD LND TVD
CFTD SFD MRD C6D CNID CLBD AUTU
ICDD CDMD LLCN EHTD MCTD
GPUD DPUD CFXA ARND OVDD AGTD CLTD LDTD ASCD
MBXD CPFA CPTA HSPD UDI ACC HBTD DDGA NAMA MIND
NRWD NRCD NROD SPKD CRD PRSD MCRD
EXRO SHL ABDD CFHD DNAA
CWND USRD BNRD OCHD RTDD FAXD
PLEV 02
AACS NO
MLWU_LANG 0
FTR DCFW 12 <ACD DN>
Table 7
LD 11 – Configure ICB ports as digital sets
Prompt Response Description
REQ NEW Add new data.
TYPE 2616 Digital telephone set M2616.