Engineering guidelines 43
Nortel Integrated Conference Bridge Service Implementation Guide
Figure 8
LAN/intranet access only – E-LAN connection
Notes
The following notes apply to LAN/intranet access only:
• The ICB does not interact with the Meridian system through the
E-LAN, so logically there is no requirement to put it there. In
addition, if the E-LAN is completely separated from the C-LAN, the
ICB cannot be in the E-LAN.
• Nortel Networks recommends that customer try not to put any BUI
traffic on the E-LAN if possible.
• Each site should select the most convenient option, taking into
account the physical LAN endpoints available near the ICB card.
G100279
ICB BUI
ICB BUI
ICB BUI
IPE Module
ICB 4
card (s)
E-LAN
10/100 Base-T
ICB LAN
connection
PBX E-LAN
connection
Router
ICB BUI
ICB BUI
traffic only
1. The ICB is not open to Customer LAN (C-LAN) traffic and you can block traffic through the router
(for example, Telnet and FTP).
2. The ICB BUI traffic is on the Embedded LAN (E-LAN).
3. If there is no router between the C-LAN ad the E-LAN, there is no BUI access from the C-LAN.
ICB BUI
World Wide
Web
Firewall
C-LAN
10/100 Base-T or 100 Base-T