Nortel Networks 8683POS Network Card User Manual


 
106 Chapter 6 Command line interface
209564-A
Figure 37 show ports stats pos felinecurrent command output
Table 38 describes the information fields for output of the show ports stats
pos felinecurrent
command.
Table 38 Information fields for output of the show ports stats pos felinecurrent
command
Field Description
PORT NUM Port number.
ERRORED SECONDS
COUNT (ES)
Errored Second (ES) is a second with one or more Coding
Violations (CV) or one or more incoming defects (for
example, SEF, LOS, AIS, LOP).
SEVERELY ERRORED
COUNT (SES)
Severely Errored Second (SES) is a second with x or more
CVs, or one or more incoming defects.
CODE VIOLATION COUNT
(CV-L)
Coding Violations (CV) are Bit Interleaved Parity (BIP)
errors that are detected in the incoming signal. CV
counters are incremented for each BIP error detected.
UNAVAILABLE SECONDS Number of seconds that the interface is unavailable.
Passport-8610:5/show/ports/stats/pos# felinecurrent
======================================================================
POS Far End Line Current Stats
======================================================================
PORT ERRORED SECONDS SEVERELY ERRORED CODE VIOLATION UNAVAILABLE
NUM COUNT (ES) COUNT (SES) COUNT (CV-L) SECONDS(UAS)
----------------------------------------------------------------------
10/5 0 0 0 0
10/6 0 0 0 0
Passport-8610:5/show/ports/stats/pos#