Remote control operation
ENGLISH
- 33
Basic Operation
Loading a saved setting
Displays the [MEMORY LOAD] menu.
Press
Attention
Setting can also be performed using the on-screen menu.
z
For details, see [MEMORY LOAD] in the [PICTURE]
menu. (
page 56)
Displaying the [VIERA LINK]
menu
You can control some functions of the external device
with this projector remote control.
Press
Note
See “Using VIERA Link” for details. (
z
page 91)
Displaying the waveform
monitor
By displaying the output signal from a connected
external device with a waveform, you can check if the
video signal (luminance) level is set to a value within
this projector’s recommended range, and can adjust it
accordingly.
Press
The settings change as follows each time the
<ENTER> button is pressed.
[FULL SCAN (Y)] [FULL SCAN (R)]
[SINGLE LINE SCAN (B)] [FULL SCAN (G)]
[SINGLE LINE SCAN (G)] [FULL SCAN (B)]
[SINGLE LINE SCAN (R)] [SINGLE LINE SCAN (Y)]
The waveform monitor disappears when the
<WAVEFORM MONITOR> button is pressed again.
Note
Setting can also be performed using the on-screen menu.
z
For details, see [WAVEFORM MONITOR] in [PICTURE]
menu. (
page 41)
[FULL
SCAN]
Checks that the waveform for each of the
Y- (brightness), R- (red), G- (green), and
B- (blue) values for the whole image is
within the recommended range.
[SINGLE
LINE
SCAN]
Checks that the waveform for each of the
Y- (brightness), R- (red), G- (green), and
B- (blue) values for an arbitrary number
of lines from the top of the screen to the
bottom is within the recommended range.
Enables more detailed conrmation than
z
[FULL SCAN].
Line position can be changed with the ▲▼
z
buttons.
The display position of the [WAVEFORM
z
MONITOR] changes depending on the line
position.
Note
Signals lower than 0 % in the waveform monitor will be
z
displayed as same as 0 % on the projected image.
[SINGLE LINE SCAN] can display horizontal lines in Y-
z
(brightness), R- (red), G- (green), and B- (blue) from the
top of the screen to the bottom more nely than [FULL
SCAN], and each item can be adjusted in the same way
as [FULL SCAN].
When selecting [FULL SCAN], the display position of the
z
waveform can be set using the ▲▼
▲
▼
buttons.
So that the display of individual adjustment screen in
z
[PICTURE] does not interfere with the waveform monitor,
the positioning of this screen differs depending on the
circumstances at the time.
The [AUTO ADJUST] is executed by pressing the
z
<DEFAULT> button while the waveform is displayed.
(
page 42)
While the waveform monitor is displayed, you cannot
z
adjust the [COLOR MANAGEMENT] settings.
When a 3D signal is being input (including converting 2D
z
to 3D), the waveform monitor cannot be displayed.
If a 3D signal is input while the waveform monitor is being
z
displayed, the waveform monitor disappears.
Resetting to the default
settings
You can reset most of the settings or adjustment
values for submenus to factory default settings.
Press
For details, see “Navigating through the menu -
Returning adjusted values to default settings” of “Menu
navigation”. (
page
37)