Panasonic PT-VW345NZU Projector User Manual


 
Attaching the air lter unit
Attach the unused air filter unit to the projector.1)
Hold the air lter unit that the tab is in up-left side in the gure, put the right side in the gure rst, and press the tab side f
until make a click sound.
Do not press any other part of the air lter unit except the frame during installation. f
Install the air filter cover.2)
Perform Step 1) in “Removing the air lter unit” ( f
Æ
page 116) in the reverse order.
Make sure that the air lter cover is closed tightly. f
Resetting the filter counter
Be sure to reset the lter counter after replacing the air lter unit.
Connect the power plug, press the <1) v/b> button on the control panel or the <b> button on the remote
control.
Press the <MENU> button to display the main menu, then press 2) as to select [PROJECTOR SETUP].
Press the <ENTER> button, press 3) as to select [FILTER COUNTER].
Press the <ENTER> button, press 4) as to select [FILTER COUNTER RESET].
Press the <ENTER> button.5)
[FILTER COUNTER RESET] conrmation is displayed. f
Press 6) qw to select [OK], then press the <ENTER> button.
The lter usage time is 0 after reset. f
Attention
Turn off the power before you replace the air lter unit. f
When attaching the air lter unit, make sure that the projector is stable, and work in an environment that is safe, even in the f
event of the air lter unit dropping.
Make sure that the air lter unit is properly attached before using the projector. If it is not attached, the projector will suck in f
dirt and dust causing a malfunction.
Do not put anything into the air vents. Doing so may result in malfunction of the projector. f
The air lter unit to be replaced should be an unused product. f
After replacing the air lter, reset the lter counter. Otherwise, “FILTER COUNTER has reached the set time.” will appear on f
screen.
Note
The replacement cycle of the air lter unit varies greatly depending on the usage environment. f
Lamp unit
The lamp unit is a consumable component. Refer to “When to replace the lamp unit” (
Æ
page 118) for details about the
replacement cycle.
It is recommended to ask an authorized engineer to replace the lamp unit. Contact your dealer.
Consult your dealer to purchase a replacement lamp unit (ET-LAV300).
Warning
Do not replace the lamp unit when it is hot. (Wait at least 1 hour after use.)
The inside of the cover can become very hot, take care to avoid burn injuries.
Tab
ENGLISH
-
117
Chapter 5 Maintenance - Replacement