Panasonic PT-VW345NZU Projector User Manual


 
Basic format
Transmission from the computer starts with STX, then the ID, command, parameter, and ETX are sent in this order. Add
parameters according to the details of control.
STX A D I1 I2 ; C1 C2 C3 : P1 P2 Pn ETX
When sending commands without parameters, a colon (:) is not necessary.*
Basic format (with sub command)
S1 S2 S3 S4 S5 E P1 P2 P3 P4 P5 P6
STX A D I1 I2 ; C1 C2 C3 : ETX
Same as basic format
Sub command (5 bytes)
Operation (1 byte)
“=” (Value specied using parameter is set)
Parameter (6 bytes)*
Symbol “+” or “
-
” (1 byte) and set value or ad-
justment value (5 bytes)
When transmitting a command which does not need a parameter, the operation (E) and parameter are not necessary.*
Attention
If a command is transmitted after the lamp starts illuminating, there may be a delay in response or the command may not be f
executed. Try sending or receiving any command after 60 seconds.
When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the response from the f
projector before sending the next command. When transmitting a command which does not need a parameter, a colon (:) is
not necessary.
Note
If a command cannot be executed, the “ER401” response is sent from the projector to the computer. f
If an invalid parameter is sent, the “ER402” response is sent from the projector to the computer. f
ID transmission in RS-232C supports ZZ (ALL) and 01 to 64, as well as 0A to 0Z groups. f
If a command is sent with a specied ID, a response will be sent to the computer only in the following cases. f
- It matches the projector ID.
- [PROJECTOR ID] (Æ page 74) is set to [ALL].
STX and ETX are character codes. STX shown in hexadecimal is 02, and ETX shown in hexadecimal is 03. f
ID designate
ZZ, 01 to 06
Start (1 byte)
(2 byte)
2 ID characters (2 bytes)
Semi-colon(1 byte)
3 command characters (3 bytes)
Colon(1 byte)*
Parameter (underned length)
End (1 byte)
ENGLISH
-
127