– 27 –
Chapter 3 Preparation — Power supply
Power supply
A battery or an external DC power supply can be used as the power supply.
Using batteries
Connection of the following batteries to the camera has been veried.
r Anton/Bauer batteries
HYTRON140
DIONIC HC/DIONIC HCX/DIONIC HD
r IDX batteries
ENDURA HL9
@@
NOTE
t Other batteries can be supported by changing [BATTERY SELECT] in [MENU] → [SYSTEM SETTINGS] → [BATTERY]. Use of batteries that are
already veried as connectable to the camera is recommended.
t Before you use a battery, charge it with a battery charger. (For details on charging, refer to each operating instructions.)
Mounting and setting battery
Using Anton/Bauer batteries
Anton/Bauer batteries
Release lever
1
Mount the Anton/Bauer battery.
2
Insert the battery terminal and slide in the direction of the arrow.
3
Set the battery type.
From [MENU] → [SYSTEM SETTINGS] → [BATTERY] → [BATTERY SELECT], select the battery type.
For details, refer to “Setting menu basic operations” (page 83).
@@
NOTE
t To remove the battery, keep the release lever of the battery holder completely down, slide the battery in the opposite direction when you mounted it.
Using V-mount type batteries
Mount the V-mount type battery plate. As shown in the illustration, insert and slide in the direction of the arrow.
Release lever
1
Mount the V-mount type battery plate.
2
Slide in the direction of the arrow.
3
Set the battery type.
fFrom [MENU] → [SYSTEM SETTINGS] → [BATTERY] → [BATTERY SELECT], select the battery type.