– 44 –
Chapter 5 Control Panel — Control panel operation
fChannel display
[1]/[2] or [3]/[4]
fLevel meter display
Displays the level represented by 19 bars. (2 dB increments)
fStandard level bar
At the −18 dB position or the −20 dB position
The standard is in [MENU] → [SYSTEM SETTINGS] → [AUDIO LEVEL] → [HEADROOM]
6 Warning/error displays
: Warning (details are displayed on the time code display in the following cases)
f[SYSTEM ERROR !]
f[TURN POWER OFF !]
f[REC WARING !]
f[CARD ERROR !] (when recording has stopped)
f[LOW BATTERY !]
f[MEDIA END !]
: Alert
7 Time code display
f[TCG 12:59:59:20]: Displays the time code generator value.
f[TCR 12:59:59:20]: Displays the time code reader value.
f[UBG AB CD EF 98]: Displays the user bits generator value.
f[UBR AB CD EF 98]: Indicates the user bits reader value.
f[Dur.00:59:59:23]: Displays the duration.
8 Lock display
Displayed when button operations are disabled due to the <LOCK> switch.
Using the control panel extension unit
The control panel can still be used after it is removed. To remove the control panel, set the <POWER> button to <OFF>.
Fig. 1 Fig. 2
Fig. 3
1
Press the <RELEASE> switch while lifting up the control panel. (Fig. 1)
The control panel will come off.
2
Attach the control panel extension unit. (Fig. 2)
3
Connect the control panel extension unit cable to the control panel. (Fig. 3)