– 29 –
Chapter 3 Preparation — Mounting and adjusting the lens
Mounting and adjusting the lens
Mounting the lens
Fig. 1 Fig. 2
Fig. 3
Lens lever
Mount cap
Fig. 4
Cable clamp
<LENS> terminal
1
Raise the lens lever and remove the mount cap. (Fig. 1)
2
Align the convex portion at the upper right of the lens mount with the concave portion at the lens mount to mount the lens. (Fig.
2)
3
Lower the lens lever to firmly clamp the lens. (Fig. 3)
4
If a cable is attached to the lens, secure the cable through the cable clamp and connect it to the <LENS> terminal. (Fig. 4)
@@
NOTE
t For handling the lens, refer to the lens operating instructions.
t When the lens is removed, install the mount cap to protect the device.
Flange lens back adjustment
The camera is equipped with the adjustment function of the ange back (distance from the lens mounting surface to the image formation surface). As
the factory setting, it is adjusted with high accuracy. If you adjust the ange back, perform the adjustment in an well-equipped environment.
@@
NOTE