Paradyne 3921PLUS Network Card User Manual


 
AT Command Set and S-Registers
5-233920-A2-GN31-30 November 1996
Table 5-3
(8 of 12)
392x
Plus
S-Registers
S-Register
DCP LCD
Command
Sequence
Description
S66 NMS Call Messages. Register determines if the modem sends information
regarding status (Call Progress) and/or sends summarized call statistics (Call
Connect) to the 6700 Series Network Management System (NMS).
Register has the following values:
0 = Call Connect & Progress
1 =
Disable
2 = Call Connect Only
3 = Call Progress Only
The factory setting is Call Connect & Progress.
Configure\Edit\
Misc
S67 Directory Location 1 Callback. Register determines if the modem uses the
single number callback function.
Register has the following values:
0 = Disable
1 = Enable
The factory setting is Disable.
Configure\Edit\
Misc
S69 Make Busy Via DTR. Register determines if the modem goes off-hook (busy)
when DTR is OFF.
Register has the following values:
0 = Disable
1 = Enable
The factory setting is Disable.
Configure\Edit\
Line Dialer
S70 V.27bis Train. Register controls the train time for V.27bis operation.
Register has the following values:
0 = Short
1 = Long
The factory setting is Short.
Configure\Edit\
Leased Line
S71 XTXC Clamps TXC. Register allows the modem’s TXC output to be clamped
off when TX Clock Source is configured for External.
Register has the following values:
0 = Enable
1 = Disable
The factory setting is Enable.
Configure\Edit\
DTE Interface
S72 RTS Antistreaming. Register determines the antistreaming operation of the
modem.
Register has the following values:
0 = Disable
1 = 10 sec
2 = 30 sec
3 = 1 min
4 = 2 min
5 = 3 min
6 = 5 min
The factory setting is Disable.
Configure\Edit\
DTE Interface