Paradyne 3921PLUS Network Card User Manual


 
COMSPHERE 392xPlus Modems
G-16 November 1996 3920-A2-GN31-30
Digital Bridging
Figure G-8 shows a sample for Digital Bridging.
Figure G-8. Sample Configuration Digital Bridge
3920Plus A Use TMp Control Template default configuration options with the following
exception:
MUX Mode
Set to DTE Bridge.
3920Plus
B, C
Use Sync Dial template default configuration options with the following
exceptions:
MUX Mode
Set to DTE Bridge.
NetworkPosition Set to Control.
Diag Connection Set to NMS(CC).
Tx Clock Source Set to Port 1.
LSD Control Set to Sim_Cntl_Car.
DTR Action Set to Ignore.
3910Plus D Use Sync Dial template default configuration options with the following
exceptions:
NetworkPosition Set to Control.
Diag Connection Set to NMS(CC).
Tx Clock Source Set to External.
LSD Control Set to Sim_Cntl_Car.