Paradyne 3921PLUS Network Card User Manual


 
Sample Configurations
G-93920-A2-GN31-30 November 1996
Configuration Options
3920Plus A Use Sync Leased (Answer) default configuration options with the following
exception:
Auto Dial Back Set to Enable.
Rate Refer to Sample Port Rate T
able in this section.
3920Plus B Use Sync Leased (Originate) default configuration options with the following
exception:
Auto Dial Back Set to Enable.
Rate Refer to Sample Port Rate T
able in this section.
Sample Port Rate Table
Port
Rate
Port
1
Port 2 Port 3 Port 4
28.8K 9600 9600 4800 4800
24.0K 9600 Disable 4800 4800
19.2K 9600 Disable 4800 4800
16.8K 9600 Disable Disable 4800
14.4K 9600 Disable Disable 4800
12.0K Disable Disable Disable 4800
9.6K Disable Disable Disable 4800
7.2K Disable Disable Disable 4800
4.8K Disable Disable Disable 4800
2.4K Disable Disable Disable Disable
Cables
Cable 1 Use
a standard, customer
-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug)
connector at one end to attach to the modem. Attach this to the connector labeled
DTE1.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is
supplied with the modem). Attach this to the connector labeled LEASED.
Cable 4 Use part number 125-0067-0031 (a 6-position, 4-wire modular cord that is
supplied with the modem). Attach this to the connector labeled DIAL.