Paradyne 8784 Network Card User Manual


 
3. Initial Startup and Configuration
8784-A2-GB20-30 February 2001
3-11
Resetting AutoRate
The Reset AutoRate function on the Control menu causes the unit to repeat the
AutoRate sequence. The unit attempts to establish the DSL link at the highest rate
(or the value of DSL Line Rate, which represents the AutoRate ceiling when
AutoRate is enabled). If the link fails, the next lower rate is tried until the link is
established.
To access the Reset AutoRate screen, follow this menu selection sequence:
Main Menu
Control
Reset AutoRate
Restoring Access to the User Interface
Improper configuration of the unit could render the user interface inaccessible. If
this occurs, access can be restored using the MCC.
Procedure
To reset the DSL Card:
1. Select
Configuration
DSL Cards
Reset Slot
.
2. Enter
DSL
nn
, where
nn
is the slot number for the DSL card you wish to reset.
3. Enter
Reset
.
4. Enter
Y
if you want to clear NVRAM also, otherwise enter
N
.
Entering
Y
restores the Default Factory Configuration.
5. Enter
Y
at the prompt to confirm.
NOTE:
When you enter
Y
, all data connectivity is interrupted.
You can also restore access to the user interface by reloading the Default Factory
Configuration options using the units menus.
Procedure
To restore access to the ATI using the units menus:
Main Menu
Configuration
Default Factory Configuration