Paradyne 8784 Network Card User Manual


 
4. Monitoring the Unit
8784-A2-GB20-30 February 2001
4-5
Self-Test Results Messages
The results of the last power-on or reset self-test appear in the middle column of
the System and Test Status screen.
Test Status Messages
The Test Status messages in the following table appear in the right column of the
System and Test Status screen.
For information on testing, refer to Chapter 5,
Testing
.
Table 4-2. Self-Test Results Messages
Message What Message Indicates What To Do
CPU Failed The CPU failed internal
testing.
1. Reset the unit and try again.
2. Call your service
representative for
assistance.
Device Failed One or more of the units
integrated circuit chips has
failed device-level testing.
DSX-1 Failed, Pt
n
The unit failed to internally
loop data on the DSX-1
Port
n
.
Failure
xxxxxxxx
An internal failure occurred.
(xxxxxxxx
represents an
8-digit hexadecimal failure
code for use by service
personnel.)
Record the failure code and
contact your service
representative.
Memory Failed The unit failed memory
verification.
1. Reset the unit and try again.
2. Call your service
representative for
assistance.
Net DSL Failed, Pt
n
The unit failed to loop data on
the network DSL circuit of
Port
n
.
Passed No errors were detected. No action is needed.
Table 4-3. Test Status Messages
Test Status Message Meaning
511 Test Active, Pt
n
A 511 Test and Monitor is active on the DSL Port
n
network
interface.
DLB Test Active, Pt
n
A Data Terminal Loopback test is active on Port
n
.
Lamp Test Active The Lamp Test is active, causing the LEDs on the front panel
to light.
LLB Test Active, Pt
n
A network Line Loopback test is active on Port
n
.
No Test Active No tests are currently running.
RLB Test Active, Pt
n
A network Repeater Loopback test is active on Port
n
.