The Device Messages in Table 6-1, Device Messages, listed in alphabetical order,
may appear in the messages area at the bottom of the ATI screens.
Table 6-1. Device Messages (1 of 2)
Device Message What Message Indicates What To Do
Access level is
Operator.
Configuration is
read-only.
The operator requested that
configuration options be
loaded, but does not have
authority to edit them.
If configuration options are to be
edited, use a Login ID that has
Administrator authority.
Cannot Save no
Login IDs with Access
Administrator
All of the login IDs being
saved have an access level
below Administrator.
Change the access level of at
least one Login ID to
Administrator so that
configuration changes can be
made. (Operator-level users
cannot make configuration
changes.) Save the Login IDs.
Command Complete Action requested has
successfully completed.
No action is needed.
Invalid Character (
x
) A nonprintable ASCII
character (
x
) has been
entered.
Re-enter information using valid
characters.
Invalid Password Login is required and an
incorrect password was
entered; access is denied.
Try again.
Contact your system
administrator to verify your
password.
Invalid Send Pattern
Already Active
A pattern test was already in
progress when the Start field
was selected.
Allow test to continue.
Select another test.
Stop the test.
Invalid
[Test]
Already
Active
The described test was
already in progress when
another selection was made.
Allow test to continue.
Select another test.
Stop the test.
Invalid Test
Combination
A loopback or pattern test
was in progress when Start
was selected to start another
test, or was active on the
same or another interface
when Start was selected.
Wait until other test ends and
message clears.
Abort all tests from the Test
menu screen.
Stop the test from the same
screen the test was started
from.
IP address not in
MCC subnet
nnn.nnn.nnn.nnn
The Peer IP address
specified is not in the same
subnet as the MCC.
Enter an IP address that is in
the same subnet as the MCC.