Paradyne 8784 Network Card User Manual


 
8784-A2-GB20-30 February 2001
7-1
7
Security
Overview
The termination unit provides several methods of security by limiting user access
to the ATI through option settings. You can:
Enable the Telnet Login Required option.
Limit the access by setting a Session Access Level option of Operator for the
Telnet Session.
Disable the access with the Telnet Session option.
See Table A-5, Telnet Session Options, in Appendix A,
Configuration Options
.
ATI Access Levels
The unit has two access levels: Administrator and Operator. The access level
determines what functions are accessible, as shown in Table 7-1, Access Levels.
Access level is also used to control access via Telnet. If the Telnet Session Access
Level is set to Administrator, a Login ID with an Operator access level is not
permitted access (see Table A-5, Telnet Session Options, in Appendix A,
Configuration Options
).
The effective access level is the more restrictive of the session access level or the
login access level.
Table 7-1. Access Levels
ATI Access to Menu Functions Administrator Operator
Status Read-Only Read-Only
Test Full Access No Access
Configuration Full Access Read-Only
Control Full Access No Access