Paradyne 8784 Network Card User Manual


 
4. Monitoring the Unit
4-2
February 2001 8784-A2-GB20-30
Viewing System and Test Status
To view System and Test Status information, follow this menu selection sequence:
Main Menu
Status
System and Test Status
The System and Test Status screen has three sections:
Health and Status
Displays messages in priority order (highest to lowest).
Refer to Table 4-1, Health and Status Messages.
Self-Test Results
Results of the Diagnostic test run on the device itself.
Refer to Table 4-2, Self-Test Results Messages.
Test Status
Currently active tests. Refer to Table 4-3, Test Status
Messages.
main/status/system Hotwire
Slot: 4 Model: 8784
SYSTEM AND TEST STATUS Page 1 of 1
HEALTH AND STATUS SELF-TEST RESULTS TEST STATUS
-------------------------------------------------------------------------------
LOS at Net, Pt
n
CPU Failed No Test Active
OOF at Net, Pt
n
Device Failed LLB Test Active, Pt
n
EER at Net, Pt
n
Net DSL Failed, Pt
n
RLB Test Active, Pt
n
LOS at DSX-1 Pt
n
DSX-1 Pt Failed, Pt
n
Lamp Test Active
Net Margin Threshold, Pt
n
Memory Failed DLB Test Active, Pt
n
Device Failed
yyyyyyyy
Passed
Download Failed
-------------------------------------------------------------------------------
ESC for previous menu MainMenu Exit