Patton electronic Model 2604 Network Card User Manual


 
16 • System Log T1/E1 DACS Administrators’ Reference Guide
112 System Log—Modify
local5(21)
local6(22)
local7(23)
Call Trace (syslogCallTrace)
Enabling this will activate the call tracing utility. This is a powerful debugging utility which will log every single
function call and return. At the death of a box the call trace will be printed out and can be sent to tech support.
This utility will take a large amount of CPU power.
disable(0)—Disable function call tracing.
enable(1)—Enable function call tracing.
dump(2)—Display function call tracing on the computer monitor.
Maintenance
This portion of the System Log—Modify window contains information described in the following section.
Maintain Flash Storage (syslogFlashClear)
Setting this variable to syslogFlashClear will cause the erasing of any system messages which have been saved in
the Flash. On reading this variable will indicate if the syslog Flash is rejecting messages because it is full.
syslogFlashOK(0)—Flash is accepting messages.
syslogFlashFull(1)—Flash is rejecting messages because it is full. To empty the flash memory, see option
syslogFlashClear(2).
syslogFlashClear(2)—Erase system messages stored in Flash. Be sure to return to the 2604’s Home page
and click on Record Current Configuration to store this change in permanent memory.