Far End Line Statistics—History 133
T1/E1 DACS Administrators’ Reference Guide 17 • T1/E1 Link
Interval (dsx1FarEndIntervalNumber)
A number between 1 and 96, where 1 is the most recently completed 15-minute interval and 96 is the least
recently completed 15-minutes interval (assuming that all 96 intervals are valid).
Errored Seconds (dsx1FarEndIntervalESs)
The number of far-end errored seconds encountered by a DS1 interface in one of the previous 96, individual
15-minute, intervals.
Severely Errored Seconds (dsx1FarEndIntervalSESs)
The number of far-end severely errored seconds encountered by a DS1 interface in one of the previous 96,
individual 15-minute, intervals.
Severely Errored Frame Seconds (dsx1FarEndIntervalSEFSs)
The number of far-end severely errored framing seconds encountered by a DS1 interface in one of the previous
96, individual 15-minute, intervals.
Unavailable Seconds (dsx1FarEndIntervalUASs)
The number of far-end unavailable seconds encountered by a DS1 interface in one of the previous 96, individ-
ual 15-minute, intervals.
Controlled Slip Seconds (dsx1FarEndIntervalCSSs)
The number of far-end controlled slip seconds encountered by a DS1 interface in one of the previous 96, indi-
vidual 15-minute, intervals.
Line Errored Seconds (dsx1FarEndIntervalLESs)
The number of far-end line errored seconds encountered by a DS1 interface in one of the previous 96, individ-
ual 15-minute, intervals.
Path Code Violations (dsx1FarEndIntervalPCVs)
The number of far-end path coding violations encountered by a DS1 interface in one of the previous 96, indi-
vidual 15-minute, intervals.
Bursty Errored Seconds (dsx1FarEndIntervalBESs)
The number of far-end bursty errored seconds (BESs) encountered by a DS1 interface in one of the previous
96, individual 15-minute, intervals.
Degraded Minutes (dsx1FarEndIntervalDMs)
The number of far-end degraded minutes (DMs) encountered by a DS1 interface in one of the previous 96,