17 • T1/E1 Link T1/E1 DACS Administrators’ Reference Guide
132 Far End Line Statistics—History
Controlled Slip Seconds (dsx1FarEndCurrentCSSs)
The number of far-end controlled slip seconds encountered by a DS1 interface in the current 15-minute inter-
val.
Line Errored Seconds (dsx1FarEndCurrentLESs)
The number of far-end line errored seconds encountered by a DS1 interface in the current 15-minute interval
Path Code Violations (dsx1FarEndCurrentPCVs)
The number of far-end path coding violations reported via the far-end block error count encountered by a DS1
interface in the current 15-minute interval.
Bursty Errored Seconds (dsx1FarEndCurrentBESs)
The number of far-end bursty errored seconds (BESs) encountered by a DS1 interface in the current 15-
minute interval.
Degraded Minutes (dsx1FarEndCurrentDMs)
The number of far-end degraded minutes (DMs) encountered by a DS1 interface in the current 15-minute
interval.
Far End Line Statistics—History
Click on Far End Line Statistics—History to display far-end statistics for previously completed 15-minute inter-
vals (see figure 50).
Figure 50. History of Far End Performance window