Pelco C2904M-B Computer Accessories User Manual


 
C2904M-B (2/05) 45
CONFIGURATION PAGE FOR COM 2 INTERFACE SETTINGS
You can use this configuration page to set the parameters of the COM2 RS-232/RS-485 serial interface port.
Table H. Interface Settings for COM2
Configuration Default
Description
Item Setting
Serial port Transparent Select the function for serial port 2 from the pull-down menu: Terminal, Transparent, or Pelco Prot. (protocol).
function
If the unit will be operated from a terminal, select Terminal. If the port must transmit data transparently, select
Transparent.
Baud rate 19200 Select any transmission rate from 300 to 57600 baud.
Data bits 8 Select the number of data bits (7 or 8) per character.
Stop bits 1 Select the number of stop bits (1 or 2) per character.
Parity check None Select the type of parity check (None, Even, or Odd).
Figure 35. Configuration Page for COM 2 Interface Settings