CONNECTING PELCONET TO A CM6700 ASCII PORT
Refer to Figure 52. This configuration lets an operator view and control cameras from a PC using a web browser. (The operator’s PC is not
shown on the diagram.)
Figure 52. Using PelcoNet with CM6700 to Provide Remote Control
Video In Video Out
Audio Out
Audio In
COM1: RS232/485 10/100 Base-T
Ethernet
Power
100-250VAC50/60Hz 100mA
COM2: RS232
PELCONET TRANSMITTER
TRANSPARENT
DATA PORT
TRANSPARENT DATA PORT
USING INTERNET EXPLORER, SET
TRANSPARENT DATA SETTINGS
ON BOTH PELCONET RECEIVER
AND TRANSMITTER:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
RS-422/485
ON OFF
KEY
RS-232
SW5 DIP SWITCH SETTINGS
13579
246810
11
12 14
13 15
16
1
2
VIDEO INPUTS
VIDEO OUTPUTS
ALARMS
(1-9)
ALARMS
(10-18)
COM 1 (1-6)
COM 2 (7-12)
CONTROL
OUTPUTS
REMOTE KEYBOARD(S)
LOCAL
KEYBOARD
1 2 3 4 5 6 7 8 9
10
11
1213 14 15 16 1718
1 2 3 4 5 6 7 8 910
11
12
0123
F
2
F
3
N
O
N
C
C
O
M
TT RR
+ +
CM6700-MXB
SET DIP SWITCH (SW5) ON CM6700-MXB TO RS-232 MODE
CM6700 MATRIX COM 2
PORT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
2-RX
3-TX
5-GND
TO NETWORK
(LAN/WAN)
PELCONET CM6700 ASCII SETUP SPECTRA COAXITRON PROTOCOL
PELCONET
TRANSPARENT
DATA PORT
2 RX.......................
3 RX.....................
5 GND.....................
CM6700-MXB
COM 2 (7-12)
7 TX
12 RX
9 GND