Pitney Bowes DM500 Postal Equipment User Manual


 
9-6 SV60890 Rev. G
9 • Maintaining and Updating
1. Lift the feed cover.
2. Push down on the moistener
brush button.
3. Grasp the moistener brush as-
sembly and pull it straight out
towards you.
4. Clean the moistening brush by
running the brush under warm
water.
5. If you need to clean or replace
the wick, go to Cleaning or
Replacing the Wick procedure
below. Otherwise go to step 6.
Cleaning or
Replacing the
Moistener Brush
Moistener Brush
Button
Moistener Brush
Assembly
Moistener
Maintenance
This section describes how to clean and/or replace the part of your mail-
ing system that moistens the flap on the envelope. This part of the mailing
system is the moistener brush assembly and consists of the moistener
brush, moistener wick and moistener tank.
If the seal quality does not improve after cleaning, you can replace the
wick or moistener brush as needed. To order replacements, refer to Chap-
ter 11, Supplies and Options in this guide. Only a Pitney Bowes represen-
tative can install a new moistener tank.
CAUTION: Never remove the E-Z Seal® bottle and the moist-
ener tank at the same time. This can result in E-Z Seal® leaking
into the mailing machine.