Polycom 7000 Network Router User Manual


 
NetEngine IAD User Guide
Voice Path Configuration 144
Configuring Start Mode on an Individual Port
1. Type 4 on the Start Mode Selection menu to select Configure
Individual Port.
2. For each port, the IAD displays the following prompt:
Port 1 [Loop] (1=Lp/2=Grnd/3=DID Wnk/4=E&M Wnk/5=Raw
ABCD/0(or Enter)=NoChange):
3. Type one of the following options for each port:
1—Loop Start
2—Ground Start
3—DID Wnk
4—E&M Wnk
5—RAW ABCD
0 or Enter—no change
4. When you’ve updated each port, Press Enter a final time.
5. The IAD updates the settings and saves the configuration.
6. Press any key to return to the Start Mode Selection menu. Press
Escape to continue with other voice path configuration.
7. Reset the IAD (page 15) when you finish voice path configuration.
Setting
SLIC
Control
Mode
To set SLIC control mode (for POTS only), type T to display the SLIC
Control Mode Selection menu:
Figure 7–5. SLIC Control Mode Selection Menu
Type the option of the control mode to set.
1. The IAD saves the mode you’ve selected and displays the menu.
2. Press Escape to return to the Voice Configuration menu and continue
with other voice path configuration.
3. Reset the IAD (page 15) when you finish voice path configuration.
*******************************************
SLIC Control Mode Selection
*******************************************
Current Control Mode = AUTO Control Mode
A. AUTO Control Mode
B. MANUAL Control Mode
NOTE
Voice gateway applications, such as CopperCom or
JetStream, overrides the value set by this command.