Raritan Computer PMG-0I-v2.0.3-E Calculator User Manual


 
CHAPTER 2: OPERATION 35
3. The Paragon Update dialog appears.
Figure 34 Paragon Update Dialog
4. If the device(s) intended to upgrade are listed in the dialog, go to Step 5. If not, click New to
add the device(s) and click each field to enter or select the appropriate data, which is
explained below:
Depending on the manner in which the computer running Paragon Manager is connect to the
desired devices, you may update the firmware through the network or the RS-232 connection.
For example, updating a Paragon I switch requires the RS-232 connection, and updating a
Paragon II switch requires the network connection.
FIELD DATA TO ENTER OR CHOOSE
Name Type the name of the desired KVM switch or user station.
IP Address/Serial
Network connection: Type the IP address of the Paragon
switch.
RS-232 connection: Choose <Default Serial> from the
drop-down list.
Port
Network connection: Type the number of the appropriate
network port. This setting must be the same as the port
setting on the OSUI of the Paragon switch. The factory
default port is 3000.
RS-232 connection: Type the number of the serial port
(COM port) that is connected to the desired KVM switch or
user station.
Encryption Key
Network connection: If you have assigned encryption keys
for the Paragon switch in the OSUI’s network setting, you
must type the same encryption keys here. Otherwise, both of
the connection and firmware upgrade will fail. If there are
no encryption keys, choose <Default No Encryption>.
RS-232 connection: Always choose <Default No
Encryption>.