SATO 10e Printer User Manual


 
Section 7. Label Sheet Commands
SATO M10e PN 9001101 Rev. A Page 7-5
Label Variable Data
COMMAND STRUCTURE <ESC>_D,aa,n....n
aa
n....nn
=
=
Field number, 01-99
Variable data, number of characters defined in the
<ESC>_N command
Example: <ESC>_D,01,AAA
Placement: Following the <ESC>_N Small Label Format command.
Default: aa = 01
COMMAND FUNCTION To specify variable data to be placed in fields defined by <ESC>_N Small
Label Format command.
PRINTER INPUT <ESC>A
<ESC>A106363060<ESC>PD,600,1020,0,0
<ESC>_F
<ESC>_N,01,04<ESC>V100<ESC>H200<ESC>L0202<ESC>XMABCD
<ESC>_N,02,07<ESC>V200<ESC>H200<ESC>L0202<ESC>B103200*11
1
<ESC>_N,03,02<ESC>V100<ESC>H400<ESC>L0202<ESC>XM99
<ESC>_D,01,AAAA<ESC>_D,02,*22222*<ESC>_D,03,22<ESC>_Q,1
<ESC>_D,01,BBBB<ESC>_D,02,*33333*<ESC>_D,03,33<ESC>_Q,2
<ESC>_D,02,*44444*<ESC>_D,03,44<ESC>_Q,4
<ESC>Z
PRINTER OUTPUT 7 labels will be printed, 1 data specified according to the first <ESC>_N
command, 2 with the data specified according to the second command and
4 with the data specified according to the third.
Special Notes
1. 1. When the Variable Data command <ESC>_D is omitted, the default
c
tent specified by the <ESC>_N command will be printed.
2. However, when the variable data specified matches that specified by th
command, the content is continued and will be printed.