Schneider Electric vw3-a58101 Electronic Accessory User Manual


 
110
ENGLISH
Maintenance
Malfunction with no fault display
Display Probable cause Procedure, remedy
No code, LEDs not
illuminated
No power supply Check power supply to speed controller
No code, green
LED illuminated,
red LED illuminated
or not illuminated
•Display module defective Change the display module
rr
rr
dd
dd
YY
YY
green LED
illuminated
Speed controller in line mode with
communication card or RS485 kit
An LI input is assigned to “Freewheel
stop” or “Fast stop”, and this input is not
switched on.
These stops are controlled by loss of
the input.
Set parameter LI4 to forced local mode
then use LI4 to confirm this forced
mode.
Connect the input to 24 V to disable the
stop.
GP_ATV58_EN.fm Page 110 Mardi, 2. avril 2002 6:09 18