Smart Technologies 600i3 Projector User Manual


 
47 | CHAPTER 6 – TROUBLESHOOTING YOUR SMART BOARD 600I3 OR SBD600I3
INTERACTIVE WHITEBOARD SYSTEM
Errors
Temperature Exceeded
If the Temperature Exceeded indicator message appears and your projector turns off
during use, one of the following issues is occurring:
Your projector overheated internally. The projector can overheat because of
blocked air vents or an internal temperature over 131°F (55°C).
The temperature outside your projector is too high.
To resolve
the temperature
exceeded error
1. Wait 15 minutes for the projector to cool down before attempting to restart.
2. Make sure that nothing is blocking the air intake and exhaust.
3. Disconnect the power cord from the power outlet.
4. Reconnect the power cord.
5. If the previous steps don’t resolve the issue and your projector still doesn’t turn on,
unplug the power cord, and then contact your authorized SMART reseller.
Fan Failure
If the Fan Failure indicator message appears and your projector turns off during use,
one of the following issues is occurring:
One of the fans has failed.
Your projector is overheating internally.
To resolve your
fan failure error
Disconnect the power cord, and then contact your authorized SMART reseller.
Error (Temperature
Exceeded)
Off Flashing Red
Error (Fan Failure) Off Solid Red
Error (Color Wheel
Failure)
Off Solid Red
Error (Lamp Failure) Solid Amber Flashing Red
Message
Power LED
(Green/Amber)
Temperature LED
(Red)