Chapter 1 DVS-9000 Functions
C:\WINNT\Profiles\Administrator\Desktop\WORK_08_21\370467401
DVS9000WW\01GB03C01-WW.fm
masterpage:Left
120
Snapshots
DVS-9000/9000SF
3-704-674-01 (1)
Key disable: When the snapshot is recalled, the key settings remain
unchanged. This can be set independently for each keyer.
Effect dissolve: The transition from the state before the snapshot recall to the
snapshot settings is carried out smoothly, by a dissolve. The dissolve
duration can be set in the Snapshot menu.
Auto transition: An auto transition starts the instant the snapshot is recalled.
The auto transition setting is valid only for M/E-1, M/E-2, M/E-3, and
PGM/PST.
Note
If both effect dissolve and auto transition are selected as attributes, the auto
transition takes precedence.
GPI output: A GPI output is sent to the allocated GPI port the instant the
snapshot is recalled.
The trigger type depends on the switcher GPI output settings made in the
Setup menu.
For details, see “Interfacing With External Devices (Device Interface
Menu)” under “Setup Relating to Switcher Processor” in Chapter 16
(Volume 2).
Table of available attributes
The attributes that can be used depend on the region, as follows.
a) Applicable only as temporary attributes, but not applicable by a menu operation.
b) Applicable only by a menu operation.
For more details, see “Saving and Recalling Snapshots” in Chapter 14
(Volume 2).
Yes: Can be used No: Cannot be used
Attribute Region
M/E-1 and PGM/PST USER 1 to USER 2 DME 1 to DME 4
Cross-point hold Yes Yes Yes
Key disable
a)
Ye s No N o
Effect dissolve Yes Yes Yes
Auto transition Yes No No
GPI outputs
b)