Sun Microsystems CP3240 Switch User Manual


 
Chapter 1 Getting Started 1-3
The 48VDC has a tolerance of 0VDC to 75VDC without damage. The switch will
operate when 48VDC is 36VDC to 72VDC, inclusive.
Caution Any input voltage outside the range of 0VDC to 75VDC can damage the
switch.
The switch requires air flow. A minimum of 100 LFM should be kept on the board at
all times. If an RTM is being used, active RTM cooling is not required.
Caution None of the integrated chips junction temperature should exceed 125˚C.
The switch requires air flow to meet this requirement. Testing should be done in
your shelf to find the quantity of air flow needed. 100 LFM is the recommended
minimum quantity of air flow.
The switch might contain materials that require regulation upon disposal. Please
dispose of this product in accordance with local rules and regulations. For disposal
or recycling information, please contact your local authorities or the Electronic
Industries Alliance at http://www.eiae.org/.